间断注射_连续光源火焰原子吸收法测多级闪蒸排水中铜_镍_刘小骐_李艳苹_潘献辉
- 78451com
-
5 次阅读
-
0 次下载
-
2020-01-13 08:45:19
文档简介:
书书书间断注射/连续光源火焰原子吸收法测多级闪蒸排水中铜、镍刘小骐,李艳苹,潘献辉(国家海洋局天津海水淡化与综合利用研究所,天津300192)摘要:采用间断注射/连续光源火焰原子吸收法测定海水淡化多级闪蒸(MSF)排放水中铜、镍的含量,方法操作简便,水样过滤酸化后直接测定。结果显示,该方法无光谱干扰,采用基体匹配法后可以消除物理干扰,标准曲线线性良好,铜和镍的加标回收率分别为96%和106%,测试精密度分别为0.8%和2.1%。铜和镍测试的检出限分别为0.027mg/L和0.024mg/L,最低检测浓度分别为0.084mg/L和0.058mg/L。关键词:连续光源火焰原子吸收;多级闪蒸排放水;铜;镍中图分类号:TU992文献标识码:C文章编号:1000-4602(2014)02-0092-03DeterminationofCopperandNickelinDischargedWaterfromMSFbyCS-FAASCombinedwithIntermittentInjectionLIUXiao-qi,LIYan-ping,PANXian-hui(InstituteofSeawaterDesalinationandMultipurposeUtilization,SOA<Tianjin>,Tianjin300192,China)Abstract:CS-FAAScombinedwithintermittentinjectionwasusedtodeterminecopperandnickelindischargedwaterfromMSF.Thismethodwaseasytooperate,thesamplecouldbedirectlydeterminedafterbeingfiltratedandacidated.Theresultshowednospectralinterference,nophysicalinterferenceaf-termatrixmatchingandgoodlinearstandardcurve.Therecoveries,RSD,LODandLOQofcopperandnickelwere96%and106%,0.8%and2.1%,0.027mg/Land0.024mg/L,0.084mg/Land0.058mg/Lrespect