Fenton_混凝沉淀法预处理锂电池加工高浓度废水_管锡珺
- 环保设计
-
62 次阅读
-
1 次下载
-
2019-03-31 10:13:16
文档简介:
Fenton_混凝沉淀法预处理锂电池加工高浓度废水_管锡珺Fenton—混凝沉淀法预处理锂电池加工高浓度废水管锡珺,仇模凯,夏丽佳,张明辉,陈修硕,刘晓茹,唐振(青岛理工大学环境与市政工程学院,山东青岛266033)[摘要]采用Fenton—混凝沉淀法处理锂电池盖板冲洗废水,研究其最佳反应条件,并探讨各因素的影响机理。结果表明:室温条件下,在Fenton反应阶段,30%H2O2投加量为12.5mL/L、FeSO4·7H2O投加量为4.0g/L、pH为2.5、反应时间为1h时,COD去除率可达91.81%;Fenton反应出水用PAC混凝沉淀法进行再处理,pH为中性或偏碱性、PAC投加量为80mg/L条件下,最终出水COD去除率可达93.9%。[关键词]Fenton试剂;混凝;沉淀;锂电池加工废水[中图分类号]X703[文献标识码]A[文章编号]1005-829X(2018)12-0076-05Pretreatmentofhigh-concentrationlithiumbatteryprocessingwastewaterbyFenton-coagulationprecipitationmethodGuanXijun,QiuMokai,XiaLijia,ZhangMinghui,ChenXiushuo,LiuXiaoru,TangZhen(SchoolofEnvironmentalandMunicipalEngineering,QingdaoUniversityofTechnology,Qingdao266033,China)Abstract:Fenton-coagulationprecipitationmethodhasbeenusedfortreatingthewastewaterfromlithiumbatterycover-boardrinsing.TheoptimalreactionconditionsofCODremovalbyFenton-coagulationprecipitationmethodhavebeeninvestigated,andthentheinfluencemechanismsoffactorsdiscussed.TheresultsshowthattheremovalrateofCODis91.81%,atroomtemperat